BKPDL - G-335C INDUSTRIAL X-RAY FIXER PART A
- MSDS: BKPDL
- Manufacturer: AGFA CORP
- Product Name: G-335C INDUSTRIAL X-RAY FIXER PART A
- National Stock Number: 6525-00N014766
Product Identification
Product ID:G-335C INDUSTRIAL X-RAY FIXER PART A
MSDS Date:06/01/1988
FSC:6525
NIIN:00N014766
Kit Part:Y
MSDS Number: BKPDL
Responsible Party
RIDGEFIELD PARK, NJ 07660
US
Emergency Phone: 303-623-5716,800-424-9300(CHEMTREC)
Info Phone: 201-440-2500
Cage: HO790
Contractor
Telephone: 210-440-2500
Cage: 59710
Ingredients
THIOSULFURIC ACID, DIAMMONIUM SALT (AMMONIUM THIOSULFATE)
CAS: 7783-18-8
RTECS: XN6465000
Fraction By Weight: 50-55%
1)
CAS: 7757-83-7
RTECS: WE2150000
Fraction By Weight: 1-5%
ACETIC ACID (SARA III)
CAS: 64-19-7
RTECS: AF1225000
Fraction By Weight: 1-5%
OSHA PEL 10 PPM
ACGIH TLV: 10 PPM/15 STEL; 9192
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYE:MAY CAUSE IRRITATION.
SKIN:NO DERMAL IRRITATION AS PER TESTS PERFORMED. INHAL:NORMALLY NO
PROBLEM, BUT INHALATION OF MIST COULD CAUSE RESPIRATORY IRRITATION.
INGEST:MAY CAUSE IRRITATION OF M UCOUS MEMBRANES OR DIGESTIVE TRACT
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES:IMMEDIATELY FLUSH W/PLENTY OF RUNNING WATER FOR AT LEAST
15 MINUTES. GET MD. SKIN:FLUSH AFFECTED AREAS PROMPTLY W/WATER FOR
15 MINUTES. REMOVE CONTAM CLOTHING. INHAL:FOR OVEREXPOSURE, REMOVE
TO F RESH AIR. INGEST:GET MD IMMEDIATELY.
Fire Fighting
Flash Point:NONCOMBUSTIBLE
Extinguishing Media:ANY APPLICABLE TO PRIMARY CAUSE OF FIRE.
Fire Fighting Procedures:EVACUATE PERSONNEL TO SAFE AREA. KEEP
PERSONNEL REMOVED & UPWIND OF FIRE. WEAR NIOSH/MSHA APPROVED SCBA
AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:WHEN HEATED TO DECOMPOSITION EMISSION OF
TOXIC FUMES OF SO*2 IS POSSIBLE.
Accidental Release
Spill Release Procedures:REVIEW FIRE/EXPLO HAZ DATA & SPECIAL PROT
INFORMATION BEFORE PROCEEDING W/CLEAN UP. USE APPROP NIOSH/MSHA
APPRVD PERSONAL PROT EQUIP DURING CLEAN UP. DIKE SPILL. PVNT LIQ
FROM ENTERING SEWERS, WATERWA YS, LOW AREAS. SOAK UP W/SAWDUST,
(SEE SUPP DATA)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN WELL VENT AREA. KEEP
CONTAINER TIGHTLY CLOSED. DO NOT STORE W/INCOMPATIBLE MATLS. DO NOT
STORE/CONSUME FOOD, DRINK, TOBACCO (SEE SUPP DATA)
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:NONE NEEDED W/WORKING MIXTURES & NORMAL ROOM
VENTILATION. IF NEEDED, USE NIOSH/MSHA APPROVED RESPIRATOR
APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:ROOM VENTILATION IS SUFFICIENT. AVOID USE OF PRODUCT IN
UNVENTILATED AREAS.
Protective Gloves:CHEMICAL GLOVES.
Eye Protection:CHEM WORKERS GOGGLES.
Other Protective Equipment:CHEMICAL APRONS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SPILL PROC:SAND, OIL DRY OR OTHER ABSORBENT MATERIAL. WASTE DISP
METH:AUTHORITY AND MAY REQUIRE PRETREATMENT. HNDLG/STOR PREC:IN
AREA WHERE THEY MAY BECOME CONTAMINATED W/MATERIAL. DISPOSE I/A/W
FEDER AL, STATE AND LOCAL REGULATIONS .
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:212F,100C
Vapor Pres:SAME/WATER
Vapor Density:SAME/WATER
Spec Gravity:1.348
pH:5.2
Evaporation Rate & Reference:SAME AS WATER
Solubility in Water:100%
Appearance and Odor:CLEAR AND COLORLESS, SLIGHT SULPHUR DIOXIDE ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ALKALIES, STRONG ACIDS, OXIDIZERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:SO*X, CO*2, CO, AMMONIA.
Disposal
Waste Disposal Methods:RECOVER NONUSABLE FREE LIQUID &/OR CONTAM WATER
& DISPOSE OF IN APPRVD/PERMITTED TREATMENT SYS. REMOVE NONUSABLE
SOLID MATL &/OR CONTAM SOIL FOR DISPOSAL IN APPRVD/PERMITTED
LANDFILL. DISCHARGE TO SEW ER REQUIRES APPROVAL OF PERMITTING
(SEESUPP DATA)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.